Fluorescent to LED conversion guide
Most commercial buildings still have fluorescent lighting somewhere: troffers in a drop ceiling, strip lights in a back room, wraparounds in a stairwell, or T5 high bays in an older warehouse. Converting those fixtures to LED cuts lighting energy roughly in half, ends tube and ballast replacements, and usually improves light quality. This guide explains the three ways to convert, how to choose between them, and which LED products replace which fluorescent lamps.

Why convert from fluorescent to LED
- Lower energy use. A typical 2x4 troffer with three 32W T8 tubes and an electronic ballast draws about 86 watts. An LED troffer with similar or better light output draws 25–50 watts.
- Less maintenance. Fluorescent tubes need replacing every few years, and ballasts fail without warning. A complete LED fixture has no tubes or ballast to replace.
- Better light. LEDs start instantly at full brightness, do not flicker as they age, and keep a consistent color across the room.
- Fewer disposal problems. Fluorescent tubes contain a small amount of mercury and often have to be recycled as universal waste. LED fixtures do not contain mercury.
- Old lamps are getting harder to find. Federal efficiency rules ended production of most T12 lamps and magnetic ballasts years ago, and several states now restrict sales of fluorescent tubes. Replacement parts for old fixtures will only get scarcer.
Three ways to convert
1. Replace the whole fixture
Remove the fluorescent fixture and install a new LED fixture in its place. In a drop ceiling, that means dropping an LED troffer or flat panel into the same grid opening. For surface-mounted fixtures, it means installing an LED strip light, shop light, or vapor tight fixture.
This is usually the best long-term choice. You get a new housing, new lens, a new driver, a full warranty on the complete fixture, and no leftover ballast or sockets that could fail later. Install time is close to what it takes to relamp and re-ballast an old fixture.
2. Install an LED tube
Swap the fluorescent tubes for LED tubes and keep the existing fixture. This is the cheapest option up front and works well when the fixtures are in good condition. There are several types of LED tube, and choosing the wrong one is the most common mistake:
- Type A (plug-and-play): works with the existing fluorescent ballast. Installation is just a lamp swap, but the ballast stays in the circuit, uses some power, and will eventually fail.
- Type B (ballast bypass): the ballast is removed and line voltage is wired directly to the sockets. No ballast to fail, slightly higher efficiency, but it requires rewiring. Single-ended tubes take power at one end only; double-ended tubes take power at both ends. The fixture must be labeled after conversion so the next person does not install a fluorescent tube by mistake.
- Type A+B (hybrid): works with a compatible ballast now and can run in ballast-bypass mode after the ballast fails. A good choice for buildings that want a quick swap today and fewer service calls later.
- Type C: uses a separate remote LED driver. Common in large retrofit programs but more involved to install.
Our 4 ft T8 LED tube produces up to 3,277 lumens with selectable wattage and color temperature on 120–277V. We also carry a 3 ft T8 LED tube and a 4 ft T5 LED tube, Type A+B at 3,000 lumens. Always check each product page for the tube type and wiring before you order.
3. Install a retrofit kit
A retrofit kit is an LED board and driver that mounts inside the existing fluorescent housing. The old tubes, sockets, and ballast come out, and the kit goes in. Kits avoid removing the fixture from the ceiling, which can matter in hard-lid ceilings or occupied spaces. The downside is that you keep the old housing and, sometimes, the old lens.
Which option should you choose?
- Choose full fixture replacement for most offices, schools, shops, and warehouses, especially when the old fixtures are yellowed, damaged, or more than 15 years old. It gives the cleanest result and the longest warranty coverage.
- Choose LED tubes when the fixtures are in good shape, the budget is tight, or you only need to convert a few fixtures. Pick Type A+B if you want flexibility.
- Choose a retrofit kit when the fixture cannot easily come out of the ceiling but you still want a ballast-free, tube-free result.
If you are converting a whole building, many owners use a mix: new fixtures in offices and classrooms, LED tubes in back rooms and closets, and new vapor tight fixtures in wet or dusty areas.

Fluorescent to LED replacement chart
These are typical matches based on light output. Check lumens on the product page rather than relying on watts alone.
- 2x4 troffer, 3 or 4 lamp T8 (about 86–112W): a 2x4 LED troffer at 35–50W, or a 2x4 LED flat panel at 40–72W for higher output. See LED troffer lights and LED flat panels.
- 2x2 troffer, 2 or 3 U-bent lamps (about 62–90W): a 2x2 LED troffer or flat panel at 25–40W.
- 1x4 troffer or wraparound, 2 lamp T8 (about 59W): a 1x4 LED troffer or panel at 25–40W, or a 4 ft LED wraparound or strip light.
- 4 ft, 2 lamp T8 strip or shop light (about 59W): a 4 ft LED strip light or LED shop light at 20–40W.
- 8 ft, 2 lamp T8 or T12 strip (about 110–150W): an 8 ft LED strip or shop light at 40–80W. See 8 ft LED lighting.
- 6 lamp T5HO high bay (about 360W): a 150–200W LED UFO high bay or linear high bay.
- 4 lamp T5HO high bay (about 240W): a 100–150W LED high bay.
- Enclosed fluorescent in wet areas: a 4 ft or 8 ft LED vapor tight fixture.
For high bays that use metal halide instead of fluorescent, see our metal halide to LED replacement chart.
How much will you save?
Here is a quick example for 100 two-lamp, 4 ft T8 strip fixtures (about 59W each) replaced with 4 ft LED strip lights set to 30W, running 3,000 hours a year at $0.15 per kWh:
- Fluorescent: 100 × 59W × 3,000 hours = 17,700 kWh, about $2,655 a year.
- LED: 100 × 30W × 3,000 hours = 9,000 kWh, about $1,350 a year.
- Savings: 8,700 kWh, about $1,305 a year, before counting tubes and ballasts you no longer buy.
Our LED energy savings and payback guide walks through the math for other fixture types, and the DLC listing and utility rebate guide explains how rebates can lower your upfront cost.
Planning the conversion
- Count and label the fixtures by room and type: troffer size, number of lamps, strip length, ceiling type.
- Check the voltage. Most of our fixtures run on 120–277V. If your building has 347V or 480V circuits, see 277V and 480V LED lighting.
- Pick one color temperature per area. 4000K is the usual choice for offices and classrooms; 5000K for shops, warehouses, and healthcare. See our color temperature guide.
- Decide on controls. Every space that sits empty for part of the day is a candidate for an occupancy sensor. See photocells and motion sensors and 0–10V dimming and lighting controls.
- Plan emergency lighting along exit paths. See emergency lighting and exit sign basics.
- Recycle the old tubes through a lamp recycler or your waste hauler.
- Have a licensed electrician do any rewiring, especially ballast-bypass tube conversions.

Common mistakes to avoid
- Ordering tubes before checking the ballast. A Type A tube will not work on an incompatible ballast, and a Type B tube must never be installed on a ballast.
- Matching watts instead of lumens. LED wattage is much lower. Compare lumen output and the light level you want.
- Mixing color temperatures in the same room.
- Leaving controls out. Occupancy sensors in restrooms, storage rooms, and private offices often save as much as the LED conversion itself in those rooms.
- Ignoring the ceiling type. Drywall ceilings need a surface mount or flange kit for flat panels; see mounting options.
Frequently asked questions
Can I just put LED tubes in my fluorescent fixtures?
Yes, if you choose the right type. Type A tubes work with a compatible ballast; Type B tubes require bypassing the ballast; Type A+B tubes work either way. Check the tube's product page for the wiring before you order.
Is it better to replace the fixture or the tubes?
Full fixture replacement usually gives the best result and the longest warranty coverage, while LED tubes cost less up front. For fixtures more than 15 years old, replacement is usually the better value.
What LED wattage replaces a 32W T8 tube?
A 4 ft LED T8 tube typically runs 12–24 watts. Our 4 ft T8 LED tube is selectable up to 24W and 3,277 lumens.
Do I need an electrician?
A plug-and-play Type A tube swap does not involve wiring. Ballast bypass tubes, retrofit kits, and fixture replacements all involve line-voltage wiring and should be done by a licensed electrician.
Will LED fixtures work with my existing wall switches?
Yes. Standard wall switches work with LED fixtures. For dimming, you need 0–10V dimmers wired to the fixture's dimming leads.
Get help with your conversion
Send us a fixture count or a floor plan and we will recommend replacements, quantities, and settings. Request a free lighting layout or contact us. Fixtures carry our 5-year warranty and 60-day returns, and orders ship in 1–3 business days per our shipping policy. Contractors can ask about wholesale orders. More guides are on our lighting resources page.