Emergency Lighting and Exit Sign Basics

Emergency lighting and exit sign basics

When the power goes out, people need to see their way out of a building. Emergency lighting and exit signs make that possible, and most commercial buildings are required to have them. This guide covers the common requirements, the types of emergency lighting, how exit signs work, and how to keep everything tested and compliant.

Commercial stairwell with emergency lighting

What the codes generally require

In the U.S., emergency lighting is generally governed by NFPA 101, the Life Safety Code, and by the building and fire codes your jurisdiction adopts, such as the International Building Code and International Fire Code. The details vary by occupancy type and location, so your local fire marshal or building official has the final word. Common requirements include:

  • Duration: emergency lighting must operate for at least 90 minutes after normal power fails.
  • Light level: an average of about 1 foot-candle along the path of egress at the start, with no point below about 0.1 foot-candle, measured at the floor.
  • Uniformity: the ratio of the brightest to the dimmest point along the path is limited, commonly to 40 to 1, so there are no dark gaps.
  • Automatic transfer: emergency lighting must come on automatically when normal power fails.
  • Testing: a functional test, commonly 30 seconds, every month, and a full 90-minute test once a year, with written records.

The path of egress includes corridors, stairs, aisles, exit passageways, and the exterior area just outside exit doors.

Types of emergency lighting

Emergency drivers inside regular fixtures

An emergency LED driver is a battery pack installed in or next to a regular fixture. During normal power, the fixture works as usual and the battery charges. When power fails, the driver runs the fixture at reduced output for at least 90 minutes. This keeps ceilings clean, with no separate emergency units, and puts emergency light right where people are used to seeing it.

See our emergency ballasts collection and the 8W emergency LED driver for flat panels, rated for 90 minutes. Several fixtures come with an emergency driver already installed, such as the 2x2 LED troffer with emergency driver and the 2x4 flat panel with emergency driver. There are also emergency drivers for linear high bays in our battery backup lighting collection.

Emergency light units

Wall- or ceiling-mounted units with their own battery and lamp heads, often called "bug eyes." They are inexpensive and easy to add, and common in back-of-house areas, mechanical rooms, and stairwells.

Exit and emergency combos

An exit sign with built-in emergency lamp heads, covering both needs with one device near a door.

Central systems and generators

Large buildings may power emergency lighting from a central inverter or generator. In that case, specific fixtures are connected to emergency circuits rather than having their own batteries.

Corridor with emergency lighting

Exit signs

Exit signs mark exits and the path to them. Common requirements include:

  • Placement: at every exit door, and along the path wherever the way to the exit is not obvious, so that no point in the path is beyond the sign's rated viewing distance, commonly 100 ft.
  • Directional arrows where the path changes direction.
  • Illumination: most exit signs are internally lit and must stay lit for 90 minutes on battery during an outage.
  • Color: red or green lettering, depending on local code. Some jurisdictions require one or the other.

Types of exit signs

  • LED exit signs use very little power and run for years without lamp changes. They are the standard choice today.
  • Exit and emergency combos add emergency lamp heads.
  • Photoluminescent signs glow after being charged by normal lighting and use no electricity, but need a minimum level of light to stay charged.

Browse LED exit signs.

Planning emergency lighting

  1. Map the path of egress from every occupied area to the exits and to a safe area outside.
  2. Mark where emergency light is needed: corridors, stairs, open areas people cross to reach an exit, restrooms in some occupancies, electrical rooms, and the exit discharge outside.
  3. Choose the method: emergency drivers in the normal fixtures, separate emergency units, or a combination.
  4. Place exit signs at each exit and along the path, with arrows where needed.
  5. Check light levels, ideally with a photometric layout. Remember that emergency drivers run fixtures at reduced output.
  6. Confirm with your local official before installation.

Our stairwell lighting collection includes fixtures for stairs and landings, and LED troffers with emergency drivers handle corridors with drop ceilings.

Testing and maintenance

  • Monthly: press the test button on each unit or driver for at least 30 seconds and confirm the light comes on.
  • Annually: run a full 90-minute test on battery and confirm lights stay on.
  • Keep records of each test.
  • Replace batteries when they fail a test. Batteries typically need replacing every several years.

Some emergency drivers and units have self-testing features that run these tests automatically and show a status light.

Frequently asked questions

How long must emergency lights stay on?

At least 90 minutes in most U.S. commercial buildings.

How bright does emergency lighting need to be?

Commonly an average of 1 foot-candle along the path of egress at the start of the test, with no point below 0.1 foot-candle.

Can I use an emergency driver instead of separate emergency lights?

Yes, in many cases. An emergency driver lets a regular fixture serve as emergency lighting. The fixture's emergency light output must still meet the required levels along the path.

Are exit signs red or green?

It depends on your local code. Many U.S. jurisdictions accept either; some require red.

Related

LED exit signs · Emergency battery backup lighting · Emergency ballasts · Stairwell lighting · Certifications and compliance · Request a layout · Lighting resources