Selectable wattage and color temperature explained
Most Steel Tech Lights fixtures let you choose the wattage and color temperature on site, with a switch on the fixture. One product can cover a dim hallway or a bright workshop, in warm or cool white, without ordering a different SKU for each. This guide explains how selectable fixtures work, how to choose settings, and how to avoid the common mistakes.

What "selectable" means
- Selectable wattage (also called power selectable or field-adjustable wattage) lets you set the fixture's power, and therefore its light output, to one of several levels. For example, our 2x4 LED troffer can be set to 25, 30, 35, 40, or 50 watts.
- Selectable CCT (correlated color temperature) lets you choose the color of the light, such as 3500K, 4000K, or 5000K. Some fixtures offer three settings ("3CCT") and some offer five ("5CCT").
The settings are usually small slide switches or dials on the driver or housing. Some fixtures have a single switch that sets both.
Why selectable fixtures help
- One fixture for many spaces. Install the same model in offices, hallways, and storage rooms, set to different levels.
- Fine-tune after installation. If a space is brighter than you need, turn the wattage down instead of removing fixtures.
- Fewer SKUs to stock. Contractors and facility managers carry one model instead of several.
- Match existing lighting. Pick the color temperature that matches the rest of the building.
- Lower energy when possible. Every step down in wattage saves energy.
How light output changes
Light output scales with wattage. At a given efficacy, a fixture set to half its maximum wattage produces roughly half its maximum lumens. The lumen figure on the product page is usually the maximum setting. Some product pages list output at each setting.
Color temperature has a small effect on output: warmer settings sometimes produce slightly fewer lumens than cooler settings.
Choosing a wattage setting
- Estimate the light level the space needs; see how many lumens do I need?.
- If you are unsure, start one step higher than you think you need. You can always turn it down.
- Use lower settings in hallways, storage, and areas with lots of daylight.
- Use higher settings for detailed work, high ceilings, and dark-colored spaces.
- Keep the same setting for all fixtures in one room so they match.
Choosing a color temperature setting
- 3000K: warm white. Lobbies, restaurants, hospitality, residential-adjacent outdoor lighting.
- 3500K: soft neutral. Reception areas, conference rooms, some retail.
- 4000K: neutral white. The most common choice for offices, schools, and general commercial spaces.
- 5000K: daylight white. Warehouses, shops, healthcare, parking lots, security lighting.
- 5700K–6500K: cool daylight. Industrial spaces and matching existing cool fixtures.
See 3000K vs. 4000K vs. 5000K for more detail.

Installation tips
- Set switches before installation. They are easier to reach on the ground than on a 25 ft ceiling.
- Turn power off before changing settings. Changing switches with power on can damage some drivers; check the instructions.
- Write the setting on your plans so future replacements match.
- Do not mix settings in one room unless it is intentional, such as a brighter task area.
Selectable wattage vs. dimming
Selectable wattage sets the maximum output during installation. 0–10V dimming adjusts output while the fixture is operating. Many of our fixtures offer both.
Selectable fixtures and rebates
Many utilities offer rebates on DLC-listed fixtures. For selectable products, DLC listings and rebate programs may be based on a particular setting. Check your program rules and the product's listing. See LED utility rebates and DLC listing explained.
Example: one fixture, three spaces
Say a building uses the same 2x4 LED troffer throughout:
- Corridors: set to 25W and 4000K.
- Offices: set to 40W and 4000K.
- Workroom: set to 50W and 5000K.
The contractor stocks one part number, and replacements are simple.
Example: high bays at different heights
A warehouse with 20 ft and 30 ft sections uses the same selectable UFO high bay. The 20 ft section is set to a lower wattage; the 30 ft section to full output. Light on the floor is similar in both.
Settings and documentation
Write the setting for each area on the lighting plan and keep a copy with building records. When a fixture is replaced years later, the new one can be set to match. Labeling the ceiling grid or fixture is also helpful in large facilities.
Common mistakes
- Leaving every fixture at the factory default without checking the light level.
- Mixing color settings in one room by accident.
- Changing switches with the power on.
- Not recording settings for future replacements.

Frequently asked questions
Can I change the wattage after the fixture is installed?
Yes, but turn off the power first, and you may need a ladder or lift to reach the switch.
Does a lower wattage setting shorten the fixture's life?
No. Running at a lower setting generally keeps the LEDs and driver cooler.
What does 5CCT mean?
The fixture offers five selectable color temperatures, such as 3500K, 4000K, 5000K, 5700K, and 6500K.
Related